Skutt EnviroVent 2 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Skutt EnviroVent 2. Skutt EnviroVent 2 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 16
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
www.skutt.com
6441 SE JOHNSON CREEK BLVD. PORTLAND, OR 97206 (503) 774--6000 SKUTT@SKUTT.COM
Revised 7/07/15
Mdf`shudOqdrrtq d
Negative Pressure
Operating Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - Operating Manual

www.skutt.com6441 SE JOHNSON CREEK BLVD. PORTLAND, OR 97206 (503) 774--6000 [email protected] 7/07/15Mdf`shudOqdrrtq dNegative PressureOperatin

Strany 2 - ConTenTs

101010CusTom InsTallaTIonsvEnting oval kilnS & kilnS ovEr 12 cubic fEEtOn kilns over 12 cubic feet, and up to 24 cubic feet, you will need a Dual

Strany 3 - InTroduCTIon

1111CusTom InsTallaTIonsuSing cEntral ducting If you have more than one EnviroVent 2, you may connect them to a central duct. If a central duct is

Strany 4 - Envirovent 2

121212operaTIonopErationLoading the Kiln The bottom kiln shelf needs to be supported at least one inch off the kiln oor to allow sufcient air circu

Strany 5 - StEp 1 - prEparation

1313troublEShootingproblem: VenT noT operaTIngPossibleCause: No Power to the vent.Solutions:Check to see the vent is plugged in.Check to make sure th

Strany 6 - Ent holE chart

141414accESSory itEmSDual Intake Kit The Dual Intake Kit is used when you are venting 2 kilns that are each at or under 12 Cubic Feet or when you are

Strany 7

1515SpecicationsMotor: 115 volt 1.4 amps 50/60 HzHeat exiting blower: 160 °F maximumBlower: 140 cfm Maximum kiln capacity for use with EnviroVent

Strany 9 - Enting 2 kilnS

222Table of ConTenTsConTenTsIntroduction ... 3Setup ...

Strany 10 - CusTom InsTallaTIons

33InTroduCTIonHow It WorksA designated number of holes are drilled in the lid and oor of the kiln either in the factory or on location. A spring loa

Strany 11 - SidE mounting

444seTupStandard EnvirovEnt 2 inStallationThis section of the manual covers standard installations of The EnviroVent 2 on a single top loading, multi

Strany 12 - Firing times

55seTupStEp 1 - prEparation• Unplug the kiln• At the time of purchase it is possible to order the kiln factory drilled. If your kiln has already be

Strany 13

666seTupKiln Chamber DepthDrill This Many Holes In SlabDrill This Many Holes In LidDrill Size Kiln Cubic Feet714 and GlazeTech 1 2 3/16” 1.1 thru 1.4E

Strany 14 - Extension Kit

77seTupStEp 5 - inStalling thE plEnum cup and Spring Stand• Using gloves to protect your hands, stretch the ex tubing to the proper length for your

Strany 15 - Reference

888seTupStEp 7 - tESting thE EnvirovEnt2 for propEr opEration• Check to make sure the plenum cup has not shifted during installation. It should be pe

Strany 16

99CusTom InsTallaTIonsdual intakE kitA Dual Intake Kit is required when you are venting 2 kilns with one Envirovent 2 or a single kiln that is greater

Komentáře k této Příručce

Žádné komentáře